dc.description | En el contexto global de la dependencia de fuentes de energía fósil en el modelo energético actual, la electricidad desempeña un papel fundamental en el crecimiento y desarrollo de las ciudades. Derivado del consumo excesivo de estas fuentes, se genera la presencia de fenómenos como el Cambio Climático, evidenciando así el uso generalizado de sistemas de climatización en edificaciones durante la temporada de verano en áreas geográficas con climas tropicales y cálidos.
El trabajo presenta un estudio comparativo anual de los impactos ambientales de dos sistemas de climatización en un espacio construido previamente: un sistema activo y un sistema pasivo. El estudio se llevó a cabo mediante la simulación de procesos sustentables utilizando el software TRNSYS® y también se evaluaron los indicadores de Calentamiento Global, Agotamiento de la Capa de Ozono y Agotamiento de combustibles fósiles, por mencionar a algunos, utilizando la metodología de Análisis de Ciclo de Vida (ACV) en el software OpenLCA. Los resultados demuestran una reducción de los impactos ambientales mediante el uso de elementos pasivos en comparación con el uso de dos aires acondicionados y su consumo eléctrico, evitando una huella de carbono de un 98% en su etapa de construcción y hasta en un 100% en su etapa de operación.
Este estudio contribuye al conocimiento sobre la importancia de implementar estrategias de climatización pasiva en edificaciones existentes como una alternativa sostenible y de bajo impacto ambiental. Los hallazgos respaldan la necesidad de promover soluciones más eficientes y respetuosas con el medio ambiente en el sector de la climatización, en línea con la transición hacia un modelo energético más sostenible y la mitigación del Cambio Climático. | es_MX |
dc.description | In the global context of dependence on fossil fuel energy sources in the current energy model, electricity plays a crucial role in the growth and development of cities. This is evident in the widespread use of air conditioning systems in buildings during the summer season in areas with tropical and warm climates.
This work presents an annual comparative study of the environmental impacts of two cooling systems in a pre-existing space: the active system and the passive system. The study was carried out through the simulation of sustainable processes using the TRNSYS® software, and various indicators such as Global Warming Potential (GWP100a), Ozone Depletion Potential, and Fossil Fuel Depletion were evaluated using the Life Cycle Assessment (LCA) methodology in the OpenLCA software. The results demonstrate a reduction in environmental impacts through the use of passive elements compared to the use of two air conditioning units and their electricity consumption, avoiding a carbon footprint of 98% during its construction stage and up to 100% during its operational stage
This study contributes to the understanding of the importance of implementing passive cooling strategies in existing buildings as a sustainable and low-impact alternative. The findings support the need to promote more efficient and environmentally-friendly solutions in the cooling sector, in line with the transition towards a more sustainable energy model and the mitigation of Climate Change. | es_MX |
dc.format | pdf - Adobe PDF | es_MX |
dc.language | spa - Español | es_MX |
dc.publisher | El autor | es_MX |
dc.rights | openAccess - Acceso Abierto | es_MX |
dc.subject | 7 - INGENIERÍA Y TECNOLOGÍA | es_MX |
dc.subject.classification | Energía electrica, climatización, sustentabilidad, Cambio Climático | es_MX |
dc.subject.classification | Electricity, cooling, sustainability, Climate Change | es_MX |
dc.subject.other | 33 - CIENCIAS TECNOLÓGICAS | es_MX |
dc.title | Análisis de la disminución de emisiones de CO2 en el acondicionamiento de un espacio con un sistema pasivo | es_MX |
dc.type | masterThesis - Tesis de maestría | es_MX |
uaem.unidad | Centro de Investigación en Ingeniería y Ciencias Aplicadas (CIICAp)- Instituto de Investigación en Ciencias Básicas y Aplicadas (IICBA) - Centro de Investigación en Ingeniería y Ciencias Aplicadas (CIICAp)- Instituto de Investigación en Ciencias Básicas y Aplicadas (IICBA) | es_MX |
uaem.programa | Maestría en Sustentabilidad Energética - Maestría en Sustentabilidad Energética | es_MX |
dc.type.publication | acceptedVersion | es_MX |
dc.audience | researchers - Investigadores | es_MX |
dc.date.received | 2023-09-21 | |