Mostrar el registro sencillo del recurso

Estudio teórico del acoplamiento de un sistema de enfriamiento a un sistema de calentamiento

dc.rights.licensehttp://creativecommons.org/licenses/by-nc/4.0 - Atribución-NoComerciales_MX
dc.contributorARMANDO HUICOCHEA RODRIGUEZes_MX
dc.contributor.authorVALENTE CANO GARCIAes_MX
dc.contributor.otherdirector - Directores_MX
dc.coverage.spatialMEX - Méxicoes_MX
dc.date2022-10-12
dc.date.accessioned2023-05-23T14:24:14Z
dc.date.available2023-05-23T14:24:14Z
dc.identifier.urihttp://riaa.uaem.mx/handle/20.500.12055/3702
dc.descriptionEn este reporte se presenta los resultados simulados para el acoplamiento del sistema de enfriamiento y calentamiento por absorción bajo diferentes condiciones de operación utilizando LiBr − H₂O. Se tienen temperaturas de calentamiento en el generador desde 338.15 a 363.15K. Los procesos de desorción y condensación se llevan a cabo a las mismas condiciones para ambos sistemas térmicos en donde el refrigerante se divide a los evaporadores de alta y baja presión. El objetivo del estudio es determinar las mejores condiciones de operación para maximizar el rendimiento de energía (COP) y exergía (ECOP). Los resultados muestran que es posible alcanzar rendimientos de energía en el sistema de calentamiento y enfriamiento de hasta 0.31 y 0.50 respectivamente, manteniendo una temperatura de activación en el generador de 363.15K. Mientras, los rendimientos de exergía en el sistema de calentamiento y enfriamiento son de 0.19 y 0.16 respectivamente. La presencia de irreversibilidades en el absorbedor y generador del sistema de calentamiento limita significativamente la eficiencia de exergía. Se ha demostrado que es posible llevar a cabo el acoplamiento, obteniendo los rendimientos de energía y exergía inferiores a los reportados para los sistemas de calentamiento y enfriamiento en forma individual debido a las condiciones de operación limitantes. Sin embargo, el rendimiento de energía general alcanza valores de hasta 0.63. Para favorecer el desempeño del sistema se consideraron diferentes estrategias, entre ellas incrementar las potencias térmicas de ambos evaporadores y del condensador con la finalidad de mejorar los rendimientos fijándolos a 2 kW y 3kW respectivamente, con esto se obtuvo mejores resultados, cercanos a los sistemas convencionales, teniéndose un ᴄᴑᴘ ᵉᶯᶠ de 0.81 y un ᴄᴑᴘ ᶜᵅᶩ de 0.37, por otro lado el rendimiento exergetico de enfriamiento y calentamiento se tienen de 0.18 y 0.21 respectivamente. Mientras tanto el coeficiente general se obtuvo de hasta 0.76.es_MX
dc.descriptionThis report presents the simulated results for the coupling of the cooling and heating system by low absorption under different. There are heating temperatures in the generator from 338.15 to 363.15K. The desorption and condensation processes are carried out at the same conditions for both thermal systems where the refrigerant is divided to the high and low pressure evaporators. The objective of the study is to determine the best operating conditions for Maximize the energy performance (COP) and exergy (ECOP). The results show that it is possible to reach energy yields in the heating and cooling system of up to 0.31 and 0.50 respectively, maintaining an activation temperature in the 363.15K generator. Meanwhile, the exergy yields in the heating and cooling system are 0.19 and 0.16 respectively. The presence of Irreversibilities in the absorber and generator of the heating system significantly limits the efficiency of exergy. It has been shown that it is possible to carry out the coupling, obtaining the energy and exergy yields lower than those reported for the heating and cooling systems individually due to the limiting operating conditions. However, the general energy performance reaches values of up to 0.63. To favor the System performance Different strategies were considered, including increasing the thermal powers of both evaporators and the capacitor in order to improve yields by setting them to 2 KW and 3KW respectively, with this better results, close to the 0.37 systems, on the other hand the exergetic cooling and heating performance are 0.18 and 0.21 respectively. Meanwhile the general coefficient It was obtained up to 0.76.es_MX
dc.formatpdf - Adobe PDFes_MX
dc.languagespa - Españoles_MX
dc.publisherEl autores_MX
dc.rightsopenAccess - Acceso Abiertoes_MX
dc.subject7 - INGENIERÍA Y TECNOLOGÍAes_MX
dc.subject.other33 - CIENCIAS TECNOLÓGICASes_MX
dc.titleEstudio teórico del acoplamiento de un sistema de enfriamiento a un sistema de calentamientoes_MX
dc.typemasterThesis - Tesis de maestríaes_MX
uaem.unidadCentro de Investigación en Ingeniería y Ciencias Aplicadas (CIICAp)- Instituto de Investigación en Ciencias Básicas y Aplicadas (IICBA) - Centro de Investigación en Ingeniería y Ciencias Aplicadas (CIICAp)- Instituto de Investigación en Ciencias Básicas y Aplicadas (IICBA)es_MX
uaem.programaMaestría en Ingeniería y Ciencias Aplicadas - Maestría en Ingeniería y Ciencias Aplicadases_MX
dc.type.publicationacceptedVersiones_MX
dc.audienceresearchers - Investigadoreses_MX
dc.date.received2023-03-16


Ficheros en el recurso

Thumbnail

Este recurso aparece en la(s) siguiente(s) colección(ones)

  • Colección Tesis Posgrado
    Se trata de tesis realizadas por estudiantes egresados de programas de posgrado de nuestra institución.

Mostrar el registro sencillo del recurso