Mostrar el registro sencillo del recurso

Concordancia de imágenes pulmonares por ultrasonido y tomografía axial computarizada, en pacientes con neumonía asociada a SARS-Cov2 confirmados por RT-PCR, ingresados en el hospital general regional con medicina familiar No. 1. Cuernavaca Morelos

dc.rights.licensehttp://creativecommons.org/licenses/by-nc/4.0 - Atribución-NoComerciales_MX
dc.contributorFERNANDO TRUJILLO OLEAes_MX
dc.contributor.authorROBERTO ANIBAL MERAZ RIVERAes_MX
dc.contributor.otherdirector - Directores_MX
dc.coverage.spatialMEX - Méxicoes_MX
dc.date2021-11-12
dc.date.accessioned2022-03-23T16:00:37Z
dc.date.available2022-03-23T16:00:37Z
dc.identifier.urihttp://riaa.uaem.mx/handle/20.500.12055/2297
dc.descriptionRESUMEN Antecedentes. El uso de la ultrasonografía pulmonar en el contexto de COVID-19, brinda muy similares con la TAC de tórax y superiores a la radiografía de tórax, mostrando gran sensibilidad en el diagnóstico de pacientes, con la ventaja adicional de la facilidad de uso en la cama del paciente, su repetibilidad, bajo costo y ausencia de exposición a radiación. Objetivo general. Determinar la concordancia de imágenes pulmonares por ultrasonido y tomografía axial computarizada en pacientes con neumonía asociada a SARS-Cov2 confirmados por RT-PCR, ingresados en el Hospital General Regional con Medicina Familiar No. 1. Cuernavaca Morelos. Material y métodos. Se realizó un estudio observacional, retrospectivo y analítico de riesgo mínimo, se seleccionaron 49 participantes mediante muestreo no probabilístico por conveniencia, derechohabientes del Instituto Mexicano del Seguro Social que acudieron a Hospital General Regional con Medicina Familiar No. 1 de Cuernavaca Morelos con enfermedad por COVID-19 confirmada por RT-PCR, analizando los resultados mediante índice Kappa para evaluar la concordancia con las imágenes obtenidas por tomografía de tórax y ultrasonografía pulmonar; tomadas en las primeras 24 horas desde su ingreso. La significancia estadística, se establece con un valor de p≤ 0.05. Se utilizó un dispositivo de ultrasonografía portátil Butterfly IQ, Ipad, recursos de la institución, del departamento de urgencias y de radiología e imagen. Los investigadores cuentan con la capacidad necesaria para los criterios a manejarse en este protocolo, además de conocimientos en metodología, radiología, ultrasonografía; así como la experiencia para la interpretación y obtención de imágenes de enfermedad por COVID-19. Resultados. Se realizaron estudios comparativos entre el ultrasonido pulmonar y la tomografía axial computarizada de tórax. El ultrasonido pulmonar mostró gran sensibilidad para la identificación de las lesiones pulmonares ocasionadas por COVID-19. Además de que presenta ventajas importantes sobre la tomografía axial computarizada de tórax; como disponibilidad, bajo costo, repetibilidad, ausencia de radiación, uso a pie de cama, etc. Conclusión. El uso del ultrasonido pulmonar guarda una excelente concordancia con la tomografía axial computarizada de tórax para la identificación de lesiones pulmonares características en la neumonía ocasionada por COVID 19, así mismo brinda la pauta para el diagnóstico temprano de pacientes con sospecha, dando un peso importante para ser herramienta de primer contacto de alta especificidad, y con ventajas claras y objetivas.es_MX
dc.descriptionABSTRACT Background. The use of pulmonary ultrasonography in the context of COVID-19, provides very similar with chest CT and superior to chest radiography, showing great sensitivity in the diagnosis of patients, with the additional advantage of ease of use in the patient bed, its repeatability, low cost and absence of radiation exposure. General objective. To determine the concordance of pulmonary images by ultrasound and computerized axial tomography in patients with pneumonia associated to SARS-Cov2 confirmed by RT-PCR, admitted to the Regional General Hospital with Family Medicine No. 1. Cuernavaca Morelos. Material and methods. An observational, retrospective and analytical study of minimal risk was carried out, 49 participants were selected through non-probabilistic sampling for convenience, beneficiaries of the Mexican Social Security Institute who attended the Regional General Hospital with Family Medicine No. 1 of Cuernavaca Morelos with COVID disease -19 confirmed by RT-PCR, analyzing the results by Kappa index to evaluate the concordance with the images obtained by chest tomography and pulmonary ultrasonography; taken in the first 24 hours after admission. Statistical significance is established with a value of p≤ 0.05. A Butterfly IQ portable ultrasonography device, Ipad, institution resources, emergency department, and radiology and imaging were used. The researchers have the necessary capacity for the criteria to be handled in this protocol, as well as knowledge in methodology, radiology, and ultrasonography; as well as experience for the interpretation and imaging of COVID-19 disease. Results. Comparative studies were carried out between pulmonary ultrasound and chest computed tomography. Pulmonary ultrasound showed great sensitivity for the identification of lung lesions caused by COVID-19. In addition to having important advantages over chest computed tomography; such as availability, low cost, repeatability, absence of radiation, bedside use, etc. Conclusion. The use of pulmonary ultrasound is in excellent agreement with chest computed axial tomography for the identification of characteristic pulmonary lesions in pneumonia caused by COVID 19, as well as provides the guideline for the early diagnosis of suspected patients, giving an important weight to be a highly specific first contact tool with clear and objective advantageses_MX
dc.formatpdf - Adobe PDFes_MX
dc.languagespa - Españoles_MX
dc.publisherEl autores_MX
dc.rightsopenAccess - Acceso Abiertoes_MX
dc.subject3 - MEDICINA Y CIENCIAS DE LA SALUDes_MX
dc.subject.other32 - CIENCIAS MÉDICASes_MX
dc.titleConcordancia de imágenes pulmonares por ultrasonido y tomografía axial computarizada, en pacientes con neumonía asociada a SARS-Cov2 confirmados por RT-PCR, ingresados en el hospital general regional con medicina familiar No. 1. Cuernavaca Moreloses_MX
dc.typeacademicSpecialization - Trabajo terminal, especialidades_MX
uaem.unidadFacultad de Medicina - Facultad de Medicinaes_MX
uaem.programaEspecialidad en Urgencias Médicas - Especialidad en Urgencias Médicases_MX
dc.type.publicationacceptedVersiones_MX
dc.audienceresearchers - Investigadoreses_MX
dc.date.received2021-11-15


Ficheros en el recurso

Thumbnail

Este recurso aparece en la(s) siguiente(s) colección(ones)

  • Colección Tesis Posgrado
    Se trata de tesis realizadas por estudiantes egresados de programas de posgrado de nuestra institución.

Mostrar el registro sencillo del recurso