Mostrar el registro sencillo del recurso

Simulación y caracterización de un sistema híbrido solar, térmico- fotovoltaico avanzado

dc.rights.licensehttp://creativecommons.org/licenses/by-nc/4.0 - Atribución-NoComerciales_MX
dc.contributorGUSTAVO URQUIZA BELTRANes_MX
dc.contributor.authorSANDRO GUADALUPE PEREZ GRAJALESes_MX
dc.contributor.otherdirector - Directores_MX
dc.coverage.spatialMEX - Méxicoes_MX
dc.date2021-03-02
dc.date.accessioned2021-03-03T02:41:01Z
dc.date.available2021-03-03T02:41:01Z
dc.identifier.urihttp://riaa.uaem.mx/handle/20.500.12055/1419
dc.descriptionRESUMEN En este trabajo se presenta una simulación y una comparación experimental de un intercambiador de calor. En el cual, se ha desarrollado un intercambiador, con un diseño novedoso, que cuenta con celdas solares adheridas a él. Por lo cual el fluido está en contacto con el intercambiador de calor y con las celdas solares. Este diseño novedoso es uno de los valores de este trabajo. Todo este sistema se encuentra instalado a la Latitud de Cuernavaca, Morelos. Para la adquisición de datos se almacenó la información en un sistema, utilizándose el software Agilent que fue Operado en Matlab, lo mismo se hizo con los valores de temperatura donde también, se utilizó termopares tipo T. Para la simulación con Ansys Fluent se tomó el mallado que hace el software por defecto. Al programa de simulación se le suministró la temperatura experimental máxima obtenida a la salida del intercambiador de calor de 71.7ºC correspondiente en el mes de Mayo 2017. Según datos obtenidos por Conagua este es el mes de mayor irradiación solar en el año en Cuernavaca. Para finalizar se obtuvieron los siguientes resultados: Eficiencia Térmica ( T), Eficiencia Eléctrica de la Celdas ( E), Eficiencia Global ( G) y los valores obtenidos; T = 78 %, E = 9.4 %, G = 87.4 %.es_MX
dc.descriptionABSTRACT In this work, a simulation and an experimental comparison of a heat exchanger are presented. In which, an exchanger has been developed, with a novel design, which has solar cells attached to it. Therefore, the fluid is in contact with the heat exchanger and with the solar cells. This novel design is one of the values of this work. All this system is installed at the Latitude of Cuernavaca, Morelos. For the acquisition of data, the information was stored in a system, using the Agilent software that was operated in matlab, the same was done with the temperature values where T-type thermocouples were also used. For the simulation with Ansys Fluent, the mesh that makes the software by default. The simulation program was supplied with the maximum experimental temperature obtained at the outlet of the corresponding 71.7ºC heat exchanger in the month of May 2017. According to data obtained by Conagua, this is the month with the highest solar irradiation in the year in Cuernavaca. Finally, the following results were obtained: Thermal Efficiency ( T),Electrical Efficiency of the Cells ( E), Global Efficiency ( G) and the values obtained; T = 78%, E = 9.4%, G = 87.4%.es_MX
dc.formatpdf - Adobe PDFes_MX
dc.languagespa - Españoles_MX
dc.publisherautores_MX
dc.rightsopenAccess - Acceso Abiertoes_MX
dc.subject7 - INGENIERÍA Y TECNOLOGÍAes_MX
dc.subject.other33 - CIENCIAS TECNOLÓGICASes_MX
dc.titleSimulación y caracterización de un sistema híbrido solar, térmico- fotovoltaico avanzadoes_MX
dc.typedoctoralThesis - Tesis de doctoradoes_MX
uaem.unidadCentro de Investigación en Ingeniería y Ciencias Aplicadas (CIICAP) - Centro de Investigación en Ingeniería y Ciencias Aplicadas (CIICAP)es_MX
uaem.programaDoctorado en Ingeniería y Ciencias Aplicadas - Doctorado en Ingeniería y Ciencias Aplicadases_MX
dc.type.publicationacceptedVersiones_MX
dc.audienceresearchers - Investigadoreses_MX


Ficheros en el recurso

Thumbnail

Este recurso aparece en la(s) siguiente(s) colección(ones)

  • Colección Tesis Posgrado
    Se trata de tesis realizadas por estudiantes egresados de programas de posgrado de nuestra institución.

Mostrar el registro sencillo del recurso