dc.rights.license | http://creativecommons.org/licenses/by-nc/4.0 - Atribución-NoComercial | es_MX |
dc.contributor | GUSTAVO URQUIZA BELTRAN | es_MX |
dc.contributor.author | SANDRO GUADALUPE PEREZ GRAJALES | es_MX |
dc.contributor.other | director - Director | es_MX |
dc.coverage.spatial | MEX - México | es_MX |
dc.date | 2021-03-02 | |
dc.date.accessioned | 2021-03-03T02:41:01Z | |
dc.date.available | 2021-03-03T02:41:01Z | |
dc.identifier.uri | http://riaa.uaem.mx/handle/20.500.12055/1419 | |
dc.description | RESUMEN
En este trabajo se presenta una simulación y una comparación experimental
de un intercambiador de calor. En el cual, se ha desarrollado un
intercambiador, con un diseño novedoso, que cuenta con celdas solares
adheridas a él. Por lo cual el fluido está en contacto con el intercambiador de
calor y con las celdas solares. Este diseño novedoso es uno de los valores de
este trabajo. Todo este sistema se encuentra instalado a la Latitud de
Cuernavaca, Morelos. Para la adquisición de datos se almacenó la información
en un sistema, utilizándose el software Agilent que fue Operado en Matlab, lo
mismo se hizo con los valores de temperatura donde también, se utilizó
termopares tipo T. Para la simulación con Ansys Fluent se tomó el mallado que
hace el software por defecto. Al programa de simulación se le suministró la
temperatura experimental máxima obtenida a la salida del intercambiador de
calor de 71.7ºC correspondiente en el mes de Mayo 2017. Según datos
obtenidos por Conagua este es el mes de mayor irradiación solar en el año en
Cuernavaca. Para finalizar se obtuvieron los siguientes resultados: Eficiencia
Térmica ( T), Eficiencia Eléctrica de la Celdas ( E), Eficiencia Global ( G) y
los valores obtenidos; T = 78 %, E = 9.4 %, G = 87.4 %. | es_MX |
dc.description | ABSTRACT
In this work, a simulation and an experimental comparison of a heat exchanger
are presented. In which, an exchanger has been developed, with a novel
design, which has solar cells attached to it. Therefore, the fluid is in contact
with the heat exchanger and with the solar cells. This novel design is one of
the values of this work.
All this system is installed at the Latitude of Cuernavaca, Morelos. For the
acquisition of data, the information was stored in a system, using the Agilent
software that was operated in matlab, the same was done with the temperature
values where T-type thermocouples were also used. For the simulation with
Ansys Fluent, the mesh that makes the software by default. The simulation
program was supplied with the maximum experimental temperature obtained
at the outlet of the corresponding 71.7ºC heat exchanger in the month of May
2017. According to data obtained by Conagua, this is the month with the
highest solar irradiation in the year in Cuernavaca. Finally, the following results
were obtained: Thermal Efficiency ( T),Electrical Efficiency of the Cells ( E),
Global Efficiency ( G) and the values obtained; T = 78%, E = 9.4%, G =
87.4%. | es_MX |
dc.format | pdf - Adobe PDF | es_MX |
dc.language | spa - Español | es_MX |
dc.publisher | autor | es_MX |
dc.rights | openAccess - Acceso Abierto | es_MX |
dc.subject | 7 - INGENIERÍA Y TECNOLOGÍA | es_MX |
dc.subject.other | 33 - CIENCIAS TECNOLÓGICAS | es_MX |
dc.title | Simulación y caracterización de un sistema híbrido solar, térmico- fotovoltaico avanzado | es_MX |
dc.type | doctoralThesis - Tesis de doctorado | es_MX |
uaem.unidad | Centro de Investigación en Ingeniería y Ciencias Aplicadas (CIICAP) - Centro de Investigación en Ingeniería y Ciencias Aplicadas (CIICAP) | es_MX |
uaem.programa | Doctorado en Ingeniería y Ciencias Aplicadas - Doctorado en Ingeniería y Ciencias Aplicadas | es_MX |
dc.type.publication | acceptedVersion | es_MX |
dc.audience | researchers - Investigadores | es_MX |